CONTEC CA10S Vet Capnograph End Tidal CO2 With SpO2 PR And RR
$1,704.16
Description
CONTEC CA10S Vet Capnograph: End-Tidal CO2, SpO2, PR & RR for Pets
The CONTEC CA10S Vet Capnograph is a compact, sidestream multi-parameter monitor designed for veterinary use. It delivers real-time End-tidal CO2 (EtCO2), Respiration Rate (RR), SpO2, and Pulse Rate (PR) to give a complete picture of a patient’s ventilation and oxygenation. When paired with a blood oxygen probe, it assesses both oxygen delivery and circulation, helping you make faster, more informed decisions in critical moments—from field emergencies to hospital care.
Why this device stands out
- Comprehensive, single-solution monitoring—EtCO2, RR, SpO2, and PR in one portable unit, ideal for fast assessments in any setting.
- Sidestream accuracy with quick response—EtCO2 measurement reaches results in under 3 seconds with atmospheric pressure and temperature compensation for stable readings across environments.
- Programmable alarms you can trust—audible and visual alarms, with adjustable limits and an over-limit alert for EtCO2 and RR to catch deviations early.
- Self-calibration and clarity—user-calibrated zero and clear prompts like “Checking Filterline” help ensure ongoing reliability without special tools.
- Long-lasting, field-ready power—rechargeable lithium battery delivers up to 8 hours of continuous use, with a robust 50 dB alarm and low-battery notifications.
- Versatile, real-world durability—dimensions 159×72×31 mm, weight 270 g, IPX1 protection, and BF-type applied parts for safe use in clinical and mobile environments.
- Flexible sampling options—disposable sampling tube (with filter cotton) that minimizes cross-contamination; optional drying tube and filter-equipped variants available.
Key specifications at a glance
- EtCO2 range 0–150 mmHg; resolution 1 mmHg; accuracy 0–40 mmHg ±2 mmHg; 41–70 mmHg ±5% of readings; 71–100 mmHg ±8% of readings; 101–150 mmHg ±10% of readings.
- RR range 2–120 rpm; resolution 1 rpm; accuracy ±1 rpm.
- SpO2 range 30–100%; resolution 1%; accuracy 70–100% ±2%; 30–69% undefined.
- PR range 25–250 bpm; resolution 1 bpm; accuracy ±2 bpm or ±2%, whichever is greater.
- Sampling 60–100 ml/min; preheat time ~2 minutes; response time < 3 seconds.
- Battery life up to 8 hours; alarm 50 dB; operating environment 5–40°C, 30–75% humidity; atmospheric pressure 700–1060 hPa.
- Power DC 3.7V rechargeable Li battery; power draw ≤1.5 VA.
Ideal users and use cases
The CA10S is purpose-built for veterinary teams operating in diverse settings:
- Pre-hospital emergency and field rescue teams needing rapid, reliable ventilation and oxygenation data.
- Emergency departments and Intensive Care Units where continuous multi-parameter monitoring can influence critical decisions.
- Operating rooms and anesthesia recovery areas in pet hospitals of all levels, enabling real-time assessment during procedures.
- Hospitals and clinics that require a portable, user-friendly monitor with robust alarms and straightforward calibration.
What problems does it solve?
- Provides immediate visibility into alveolar ventilation and pulmonary perfusion via EtCO2 and RR, enabling quicker detection of ventilation issues.
- Offers continuous oxygenation insight with SpO2 and PR, helping guard against hypoxia and perfusion problems during anesthesia, sedation, or respiratory distress.
- Reduces downtime with self-calibration, clear prompts, and replaceable sampling tubes designed to minimize cross-contamination and water ingress risks.
- Delivers a compact, battery-powered solution that can accompany patients from the field to the bedside without sacrificing data quality.
Practical tips and insights
Maximize performance and longevity with these practical practices:
- Use the disposable sampling tube for each patient and replace after roughly 30 minutes to prevent water ingress and equipment damage.
- Preheat the device for about 2 minutes before initial use and verify zero calibration to ensure accuracy.
- Keep the SpO2 probe properly positioned and secure during transport or procedures to minimize motion artifacts and maintain stable SpO2 readings.
- Monitor the alarms and adjust thresholds to reflect patient-specific targets, then silence as appropriate to avoid alarm fatigue.
- Regularly check atmospheric pressure and environmental temperature compensation to maintain accurate EtCO2 readings in varying rooms or outdoors.
What’s included and optional
: User Manual, Sampling tube (Cannula tube with filter cotton), USB cable. - Optional configurations: Sampling tube with filter cotton and drying tube; Digital animal tongue clip SpO2-6P (1 m, Gray).
Why choose the CA10S for your veterinary practice
Uniquely designed for veterinary medicine, the CA10S delivers a precise blend of speed, accuracy, and practicality. Its compact form fits busy clinics and mobile teams alike while the robust alarm system and user-friendly calibration ensure dependable monitoring in high-stakes moments. By integrating EtCO2, RR, SpO2, and PR into a single, portable device, it helps clinicians quickly identify ventilation or oxygenation problems, guide interventions, and improve patient outcomes.