IBP Cable Sensor Invasive Blood Pressure Module For CONTEC Patient Monitor
$499.32
Descripción
IBP Cable Sensor Invasive Blood Pressure Module for CONTEC Patient Monitors
Designed to deliver precise invasive blood pressure measurements with CONTEC patient monitors, this IBP cable sensor module offers dual-channel monitoring across arterial and venous pressures. Compatibility is determined by the monitor interface version, so choose the IBP version that matches your specific CONTEC interface to ensure a secure, plug-and-play connection.
Key Features
- Plug-and-play IBP technique that pairs with CONTEC monitors via the correct interface version
- Dual-channel measurement: CH1 and CH2 report SYS, DIA, and MAP for arterial and venous readings
- Compatible with adult, pediatric (enfant), and infant patients
- Low-power operation with no special power supply required
- Automatic digital data processing for clear, reliable trends
- Time-based zero calibration with a dedicated calibration function
- Supports monitoring of ART, PA, CVP, RAP, LAP, ICP, and P1–P2 Expand Pressure
Technical Specifications
- Measure ranges: ART 0–40 kPa; PA -0.8–16 kPa; CVP/RAP/LAP/ICP -1.3–5.3 kPa; P1–P2 -1.3–40 kPa
- Zero calibration: every time the module is used
- Calibration: termly or when using a new sensor
- Sensitivity: 5 μV/V/mmHg
- Impedance range: 300–3000 Ω
- Resolution: 1 mmHg
- Accuracy: ±2% or 1 mmHg (whichever is larger)
- Update interval: ~1 second
- Display mode: shown on the corresponding monitor screen
Why This IBP Module Stands Out
- Precise, multi-parameter hemodynamic data in a compact, single-component setup that integrates seamlessly with CONTEC systems
- Dual-channel design enables simultaneous arterial and venous pressure monitoring, speeding clinical decisions in critical care
- Dedicated calibration routines ensure measurement integrity over time, with easy re-zeroing for each use
- Broad measurement range supports complex hemodynamic scenarios—from routine arterial BP checks to advanced pressures like ICP and P1–P2 Expand Pressure
Ideal Use Cases
- Intensive Care Unit (ICU) patients requiring continuous arterial and venous pressure monitoring
- Operating room anesthesia settings where rapid, accurate BP readings are critical
- Pediatric and neonatal monitoring scenarios where small pressure variations matter
- Situations demanding simultaneous ART, PA, CVP/RAP/LAP/ICP, and P1–P2 pressure tracking for comprehensive hemodynamics
Practical Setup and Care Tips
- Verify the monitor interface version and select the matching IBP version to ensure correct connection
- Securely connect the IBP cable to the CONTEC monitor and confirm a stable transducer setup with no leaks
- Perform zero calibration with the patient in a stable position; rely on the monitor’s automatic data processing for trend reliability
- Implement termly calibration or recalibration whenever swapping sensors to maintain accuracy
- Leverage dual-channel data in conjunction with other monitor metrics to form a comprehensive hemodynamic picture
Note: In mmHg equivalents, ART typically ranges from 0–300 mmHg, PA from roughly -6 to 120 mmHg, CVP/RAP/LAP/ICP from about -11 to 40 mmHg, and P1–P2 up to ~300 mmHg. Exact values depend on patient physiology and sensor calibration.