Veterinary Mainstream Capnograph with EtCO2 & Respiratory Rate Display
$740.10
Description
Bring end-tidal carbon dioxide, airway respiratory rate and a respiratory waveform together with this veterinary mainstream capnograph. The compact blue-and-silver unit displays EtCO2 and breathing-rate information on its front screen, with physical controls beside the display and a transparent airway adapter pictured in the gallery.
Designed for evaluation within a professionally managed veterinary monitoring workflow, the device offers audible and visual alarms with user-set limits, user-performed zero calibration and power from two AAA batteries. Have the responsible veterinary professional review the supplied documentation and confirm circuit compatibility and patient suitability before procurement.
For purchasers already familiar with the manufacturer's brand and the CA10M model. This is not an introductory home pet-health device. If unfamiliar with the equipment, review the manufacturer's documentation and obtain qualified veterinary guidance before ordering. Contact us for destination and supply review.

Why This Veterinary Capnograph
- Values and waveform together: EtCO2, airway respiratory rate and a respiratory trace share one screen for review by the responsible professional.
- Mainstream configuration: The pictured adapter fits into the device's sensing area. Confirm the complete airway setup against the supplied instructions rather than assuming universal connection compatibility.
- Adjustable warning limits: Audible and visual alarms have user-set limits for configuration within an established veterinary protocol.
- Battery-powered format: Two AAA batteries supply power, allowing the team to plan a battery-check routine alongside other pre-use checks.

What Is It For & How It Helps
The listed application is veterinary respiratory monitoring, including evaluation for anaesthesia, emergency and post-anaesthesia workflows. EtCO2 is end-tidal carbon dioxide; AwRR is airway respiratory rate. These measurements do not replace a veterinary examination or the broader monitoring selected by the responsible clinician.
Before purchase, the veterinary team should confirm the intended use, adapter and circuit compatibility, patient suitability, required consumables and operating procedures. The pictured animals are application illustrations, not a guarantee that one configuration suits every species, size or airway arrangement.
Set up the unit so the screen remains visible without adding strain to connections. Use the supplied instructions for zeroing, alarm configuration and pre-use checks. A warning feature complements direct professional supervision rather than making the system suitable for unattended care.
Capnograph Specifications
| Format | Veterinary mainstream capnograph |
|---|---|
| Measurements | EtCO2 and airway respiratory rate |
| EtCO2 range | 0–150 mmHg |
| Respiratory rate range | 2–150 breaths per minute |
| Display | Numeric values and respiratory waveform |
| Alarms | Audible and visual; user-set limits |
| Zero calibration | User-performed zeroing |
| Power | Two AAA batteries |
| Controls | Four physical front buttons |
| Pictured accessory | Transparent airway adapter |
Measurement ranges are device specifications, not clinical target values. Confirm the supplied accessory configuration and battery inclusion before ordering.
Tips & Suggestions

Reviewing procurement requirements
Compare the manufacturer's documentation with your veterinary team's intended monitoring workflow. Confirm the model, required accessories and intended patient range before choosing equipment for a clinical station.
Checking circuit compatibility
Have the responsible clinician check the adapter and circuit requirements against the supplied instructions. Do not infer fit or suitability from a connector photograph alone, particularly when adapting an existing setup.
Planning screen visibility
Position the unit so the responsible operator can see numeric values and the waveform without pulling on connections. Leave controls accessible and keep surrounding equipment from obscuring the display.
Preparing alarm settings
Use the supplied instructions and your clinical protocol to configure warning limits. Check that the team understands the indication and response process rather than relying on a warning sound in place of supervision.
Establishing pre-use checks
Include battery condition, device inspection and the documented zeroing process within the team's preparation routine. Keep the instructions available rather than treating user-performed zero calibration as automatic calibration.
Organising consumables
Confirm the adapter configuration and any replacement requirements before introducing the unit into service. Follow the manufacturer's hygiene and reuse instructions rather than assuming a transparent accessory is reusable.
Moving and storing equipment
Protect the screen and sensor area, avoid strain on the adapter and follow the supplied storage guidance. Inspect the unit before returning it to service and keep a documented response plan for equipment failure.
Not Ideal For
Not an introductory home pet-health monitor or a substitute for veterinary care. Do not purchase for human use under this veterinary listing, assume universal circuit compatibility or rely on alarms for unattended monitoring. Not intended for buyers unfamiliar with the manufacturer's brand and this model who need initial product-selection guidance.
Frequently Asked Questions
What does this capnograph display?
It displays end-tidal carbon dioxide, airway respiratory rate and a respiratory waveform. The listed ranges are 0–150 mmHg for EtCO2 and 2–150 breaths per minute for respiratory rate.
Is this for home pet monitoring?
This listing is for veterinary mainstream monitoring equipment to be evaluated and used by an appropriately trained veterinary team. It is not an introductory home pet-health device or a replacement for veterinary assessment.
Does it have alarms and zero calibration?
It has audible and visual alarms with user-set limits and a user-performed zero calibration function. Follow the supplied instructions and your veterinary team's protocol.
How is it powered?
It uses two AAA batteries. Confirm battery inclusion and follow the supplied instructions for compatible batteries, installation and replacement.
Should I contact you before ordering?
Yes. Contact us for destination and supply review, and confirm the selected model and accessory configuration. Purchase only if you are already familiar with the manufacturer's brand and this model and have confirmed suitability with the responsible veterinary professional.
Important Notices & Disclaimers
Buyer familiarity required: Intended for purchasers who already know the manufacturer's brand, this model and its operating requirements. Review the documentation and confirm suitability with a qualified veterinary professional before ordering. Familiarity does not replace training.
Veterinary equipment, not a substitute for professional assessment or emergency care. Follow supplied operating, patient-safety, hygiene and battery instructions. Measurements and alarms require professional interpretation and supervision. Do not change treatment based only on a displayed value.
Do not immerse the device or treat it as waterproof or dustproof. Keep liquids away from electrical and sensor components. Stop use if the device or adapter is damaged and follow the manufacturer's service instructions.
Destination review: Products may be restricted in some countries. Contact Très Elite through the official contact form before ordering, or submit an order for destination feasibility review. Orders that cannot be supplied will be cancelled. Uncaptured authorisations may be voided where applicable; collected payments require refund handling. Temporary bank authorisation holds may appear.
Shipping & Delivery
Destination and order checks
Contact us for destination and supply review before ordering. Check the full address including unit and postal code, recipient/contact details, selected model, design, dimensions, accessory contents and intended quantity. Read Quick Answers (Order & Shipping FAQs) on the product listing.
Processing and delivery methods
Most standard orders require approximately 3–7 business days of processing before shipment; carrier transit is additional. Product-specific estimates take priority. Standard is not express. Express, where offered, shortens transit but does not bypass sourcing, preparation or order review, or guarantee an event date. See Shipping & Handling and review the estimate for your selected method and destination.
For standard holiday delivery, plan at least 2–3 weeks ahead with additional peak buffer and any longer product-specific estimate. This is planning guidance, not an arrival guarantee.
Correction requests within 60 minutes
Report address, recipient/contact, product/variant, size, colour or quantity errors through the official contact form or website live chat within 60 minutes of ordering, including weekends and holidays. Timely requests do not guarantee correction because processing may already have begun. Do not rely on replies to automated order emails.
International shipping and customs
VAT, customs and duties treatment varies by destination, product, carrier and shipping arrangement. Where expressly identified as duties prepaid/DDP, included import charges are handled in advance; otherwise recipient charges may apply and customs may request documentation. See International Shipping or ask through the official contact form.
Arrival inspection and returns
Report damage, defects or incorrect supply through the official contact form with order details, clear photographs and a clear video showing the issue. Retain the item and packaging; do not return without approval. Change-of-mind and customer selection errors are normally ineligible under the published terms; discretionary approval may apply. This does not replace assistance for damage, defects or fulfilment errors. Review Returns & Exchanges and Contact Us.
Device features and sample screen values are not clinical targets, a performance guarantee or destination authorisation. Follow supplied instructions and applicable store policies.

