{"product_id":"ibp-cable-sensor-ibp-module-invasive-blood-pressure-module-for-contec-patient-monitor","title":"IBP Cable Sensor Invasive Blood Pressure Module For CONTEC Patient Monitor","description":"\u003cdiv\u003e\n\u003ch1\u003eIBP Cable Sensor Invasive Blood Pressure Module for CONTEC Patient Monitors\u003c\/h1\u003e\n\u003cp\u003eDesigned to deliver precise invasive blood pressure measurements with CONTEC patient monitors, this IBP cable sensor module offers dual-channel monitoring across arterial and venous pressures. Compatibility is determined by the monitor interface version, so choose the IBP version that matches your specific CONTEC interface to ensure a secure, plug-and-play connection.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003ePlug-and-play IBP technique that pairs with CONTEC monitors via the correct interface version\u003c\/li\u003e \u003cli\u003eDual-channel measurement: CH1 and CH2 report SYS, DIA, and MAP for arterial and venous readings\u003c\/li\u003e \u003cli\u003eCompatible with adult, pediatric (enfant), and infant patients\u003c\/li\u003e \u003cli\u003eLow-power operation with no special power supply required\u003c\/li\u003e \u003cli\u003eAutomatic digital data processing for clear, reliable trends\u003c\/li\u003e \u003cli\u003eTime-based zero calibration with a dedicated calibration function\u003c\/li\u003e \u003cli\u003eSupports monitoring of ART, PA, CVP, RAP, LAP, ICP, and P1–P2 Expand Pressure\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eMeasure ranges: ART 0–40 kPa; PA -0.8–16 kPa; CVP\/RAP\/LAP\/ICP -1.3–5.3 kPa; P1–P2 -1.3–40 kPa\u003c\/li\u003e \u003cli\u003eZero calibration: every time the module is used\u003c\/li\u003e \u003cli\u003eCalibration: termly or when using a new sensor\u003c\/li\u003e \u003cli\u003eSensitivity: 5 μV\/V\/mmHg\u003c\/li\u003e \u003cli\u003eImpedance range: 300–3000 Ω\u003c\/li\u003e \u003cli\u003eResolution: 1 mmHg\u003c\/li\u003e \u003cli\u003eAccuracy: ±2% or 1 mmHg (whichever is larger)\u003c\/li\u003e \u003cli\u003eUpdate interval: ~1 second\u003c\/li\u003e \u003cli\u003eDisplay mode: shown on the corresponding monitor screen\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eWhy This IBP Module Stands Out\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003ePrecise, multi-parameter hemodynamic data in a compact, single-component setup that integrates seamlessly with CONTEC systems\u003c\/li\u003e \u003cli\u003eDual-channel design enables simultaneous arterial and venous pressure monitoring, speeding clinical decisions in critical care\u003c\/li\u003e \u003cli\u003eDedicated calibration routines ensure measurement integrity over time, with easy re-zeroing for each use\u003c\/li\u003e \u003cli\u003eBroad measurement range supports complex hemodynamic scenarios—from routine arterial BP checks to advanced pressures like ICP and P1–P2 Expand Pressure\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eIntensive Care Unit (ICU) patients requiring continuous arterial and venous pressure monitoring\u003c\/li\u003e \u003cli\u003eOperating room anesthesia settings where rapid, accurate BP readings are critical\u003c\/li\u003e \u003cli\u003ePediatric and neonatal monitoring scenarios where small pressure variations matter\u003c\/li\u003e \u003cli\u003eSituations demanding simultaneous ART, PA, CVP\/RAP\/LAP\/ICP, and P1–P2 pressure tracking for comprehensive hemodynamics\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003ePractical Setup and Care Tips\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eVerify the monitor interface version and select the matching IBP version to ensure correct connection\u003c\/li\u003e \u003cli\u003eSecurely connect the IBP cable to the CONTEC monitor and confirm a stable transducer setup with no leaks\u003c\/li\u003e \u003cli\u003ePerform zero calibration with the patient in a stable position; rely on the monitor’s automatic data processing for trend reliability\u003c\/li\u003e \u003cli\u003eImplement termly calibration or recalibration whenever swapping sensors to maintain accuracy\u003c\/li\u003e \u003cli\u003eLeverage dual-channel data in conjunction with other monitor metrics to form a comprehensive hemodynamic picture\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eNote: In mmHg equivalents, ART typically ranges from 0–300 mmHg, PA from roughly -6 to 120 mmHg, CVP\/RAP\/LAP\/ICP from about -11 to 40 mmHg, and P1–P2 up to ~300 mmHg. Exact values depend on patient physiology and sensor calibration.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CONTEC","offers":[{"title":"used for old version","offer_id":43761262723108,"sku":"1.4.11.00007","price":499.32,"currency_code":"USD","in_stock":true},{"title":"used for new version","offer_id":43761262755876,"sku":"1.4.11.00008","price":499.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2281\/7497\/files\/1_2_73b71585-004e-4f8e-a9a3-29b3fecd4db7.jpg?v=1772951472","url":"https:\/\/www.treselite.com\/es\/products\/ibp-cable-sensor-ibp-module-invasive-blood-pressure-module-for-contec-patient-monitor","provider":"Très Elite","version":"1.0","type":"link"}